久久综合九色综合97_久久久,亚洲婷婷第一狠人综合精品,久久精品不卡,中文字幕影院,ppypp欧美日韩一区二区,清纯唯美一二区jk,五月天婷婷综合网

AI Series Multi-Functional Communication Controller

TCP Multifunction Communication Controller: Convert AIbus protocol to Modbus-TCP protocol

EtherCAT Multifunction Communication Controller: Convert Modbus-RTU protocol to EtherCAT protocol

DeviceNET Multifunctional Communication Controller: Convert Modbus-RTU protocol to DeviceNet protocol

TCP Multi-Functional Communication Controller:

1. The default version is used to convert the AIbus protocol to the Modbus-TCP protocol.

2. Designed with DIN rail mounting and bottom bus terminals, the AI-TCP1 default version supports connection to 36 AIbus instruments; AI-TCP2 features 2 RS485 ports (the second RS485 port is a standard terminal) and can connect up to 72-channel AIbus instruments in its default version.

3. The AI-TCP1-RTU and AI-TCP2-RTU can be used to connect 8xx8 series instruments with Modbus-RTU protocol, converting the Modbus-RTU protocol to Modbus-TCP protocol. The AI-TCP1-RTU supports up to 12 8xx8 instruments, while the AI-TCP2-RTU, with dual serial ports, can support up to 24 8xx8 instruments. It’s best to note any instruments with special connections when placing your order.

4. AI-TCP1 supports transparent transmission mode.

5. Features include optoelectronic isolation, extended communication distance, and accelerated data acquisition speed.

6. Built-in 7 sockets allow up to 7 host computers to access simultaneously.

7. The default power supply is 24VDC (model suffix -24VDC).


EtherCAT Multi-Functional Communication Controller:

1. Used to convert the Modbus-RTU protocol to the EtherCAT protocol.

2. Designed with DIN rail mounting and bottom bus terminals, AI-EtherCAT8 supports connection to 8 AI instruments (Modbus protocol required), or 1 unit of 8x88, or 2 units of 8x48; AI-EtherCAT16 supports connection to 16 AIbus instruments, or 2 units of 8x88, or 4 units of 8x48; AI-EtherCAT32 supports 4 units of 8x88.

3. Features include optoelectronic isolation, extended communication distance, and accelerated data acquisition speed.

4. The default power supply is 24VDC (model suffix -24VDC).


DeviceNET Multi-Functional Communication Controller:

1. Capable of converting the Modbus-RTU protocol to the DeviceNet protocol, supporting 3 Modbus-RTU commands (03H, 06H, and 10H).

2. Featuring a DIN rail and bottom bus terminal design, it can connect to multiple Modbus RTU slave devices via the bottom RS485 interface.

3. Allow flexible configuration of Modbus-RTU registers and mapping of DeviceNet memory addresses through dedicated configuration software, enabling data communication between multiple Modbus devices and the host computer; use an open five-pin pluggable terminal.

4. DeviceNet communication baud rates selectable at 125K, 250K, and 500K; support up to 512 bytes of input and 512 bytes of output.

File Name Number Associated Model Version Preview Download
Yudian AI-TCP (8x88 Special Edition) Protocol Converter Manual S243-00 8x88 TCP

TOP

Contact Sales

Whats App

TOP

故城县| 博罗县| 石台县| 浑源县| 木里| 历史| 屏南县| 浦东新区| 台湾省| 漠河县| 库尔勒市| 凤凰县| 蒙阴县| 汶上县| 柳江县| 台江县| 依兰县| 赣州市| 肇东市| 合水县| 黑龙江省| 扬州市| 永嘉县| 阿勒泰市| 潼南县| 靖边县| 惠来县| 永德县| 东阳市| 舟山市| 手机| 康平县| 那坡县| 尉犁县| 白城市| 吉林省| 方正县| 寿光市| 五寨县| 南丰县| 西盟|